Biowater generators:
With high capacity and low power consumption these units are unique and unmatched. One single unit can cover large areas with hydrogen, oxygen or air mixture.
NanoBubbles (Ultrafine bubbles):
Hydroxyl radicals (HO) formed by nanobubbles is one of the most efficient disinfection methods available and do not require additional chemical treatments. Hydrogen is the most extreme but both air and oxygen is over 100 times more efficient than Titanium AOP UV that is the most used on the market today.
Concerns:
Not at all, Biowater is safe for use in general water treatment as sewage plants and drinking water. Drinking Biowater is considered as a benefit for the human body and all surfaces that comes in contact will be disinfected.
Hydrogen, oxygen and air is safe for use in all areas and creates hydroxyl radicals that is one of the most powerful water treatment media, hydroxyl radicals are a 50% stronger oxidizing agent and does the job 3000 times faster than chlorine.
Capacity:
Standard units range from 1,2 to 228 m3/h and the ORP can be regulated by the amount of gas/flow injected into the water. Below is a view of different media that is tested and verified. By reducing the ORP the bioavailability for iron, zinc, calcium and magnesium will be kept and improved and also be
Complies to:
WET compliant (Whole Effluent Toxicity)
Veiledning til drikkevannsforskriften §13: Vannbehandling
FOR-2016-12-22-1868: Forskrift om vannforsyning og drikkevann
Livsmedelsverkets föreskrifter (SLVFS 2001:30) om dricksvatten
Drikkevandsbekendtgørelsen
Terveysministeriön asetus talousveden laatuvaatimuksista 19.5.2000/461
Reglugerd um neysluvatn 2001
The Water Supply (Water Quality) Regulations 2000 (England and Wales) (Similar Regulations apply in Scotland and Northern Ireland)
What is the best choice?
Biowater Air is the most economical tool on the market, it is completely maintenance free, do not use any kind of power and is good for use for disinfection in hospitals, agriculture, aquaculture and other areas. With Biowater Air useful minerals as iron, zinc, calcium and magnesium will be kept and strengthened. The water surface tension will also be reduced for better performance which is very useful for greasy applications where water easier will mix with oil and grease.
Biowater Hydrogen is an extreme tool for applications like lake aeration, sewage treatment, food, fish and meat processing plants etc. Power like this is not needed in normal application and will also add additional product cost. Hydrogen is splitted by use of Quantum generators that generates between 1,6 ppm and 2.0 ppm hydrogen. This setup can only be used in fresh water and for seawater application a separate hydrogen generator is needed.
Biowater Hydrogen at 1,6 - 2,0 ppm have an ORP of -850 mV which is maximum under atmospheric pressure. At higher water pressure the ORP will be a lot higher but is not possible to measure due to instrument limitations.
Below added features can easily be obtained with Biowater Air
Reduced methane pollution Clean water pipes Biofilm removal Tasty water Kills bacteria and viruses Kill fungus and moulds Keeps RO systems clean Reduced N-Hexane Ammonia reduction Antifouling
Better heat transfer Cost saving Better growth Aeration Chemical reduction
Reduced smell Disinfection Scaling removal Reduced maintenance Suppression of pathogens
Disease prevention Algae removal
Lake cleaning:
Barge for aeration of lakes, even completely dead lakes can be braught back to life. Mild treatment can be done with the Quantum generator and combining it with the Biowater unit heavy deluted water will be cleaned.
• Introduces three forms of gas into the water: Hydrogen,
dissolved oxygen and nanobubbles
• Very high oxygen transfer efficiency (OTE) regardless of
water depth: >85%
• Evenly oxygenates the entire water column
• Stable dissolved oxygen levels
• Superior water quality and disease prevention
• Resets sediments to its original state
• Efficient media for stopping algae blooms, and killing
toxins and cyanobacteria
• 1,6-2,0 PPM Hydrogen is pulled out from the water
which equals 19 – 24 liter H2 pr m3 of water
• In the same process is 6 - 9 liter oxygen pr m3 of water
also added
Area of use
Biowater Hydrogen
Dental care:
• Prevents dental diseases
• Eliminates bacterias
• Prevents and removes biofilm
• Eliminates patogens
• Prevents and removes plaque (documented)
• Prevents and removes scaling
• Disinfects pipes and equipment
• Assists in clean and safe surgery
• Bottled Biowater is a very good tool for home treatment after surgery and for plaque removal
Fish and meat processing plants:
• Ice frozen with hydrogen water keeps the fish fresh a lot longer than normal water
• Biofilm, algae, algae toxins and scaling removal
• Evenly oxygenates the entire water column
• Keeps all piping, pumps and machinery clean and 100% desinfected at all time
• Reduced Maintenance Costs
• All areas washed with ultrafine bubbled water will be desinfected, included handwash and bodywash
• No more bad smell
• Significant inhibition effect on corrosion
• Cleans wastewater and drain pipes
• Keeps holding tanks clean
• Keeps waste tanks clean and odour free
• Increase the shelf time without bad smell and creation of ammonia
Area of use
Biowater
Municipal water supply:
• Keeps water free from e-coli, salmonella, legionella, mycobacterials, listeria, camploybacter etc.
• Biofilm, algae, algae toxins and scaling removal
• Evenly oxygenates the entire water column
• Keeps all piping, pumps and machinery clean and 100% desinfected at all time
• Reduced Maintenance Costs
• Significant inhibition effect on corrosion
• All areas washed with ultrafine bubbled water will be disinfected, included handwash and bodywash
• Less or no chemicals for laundry
• Cleans wastewater and drain pipes from end users
• All areas where nanobubbled water is used will be desinfected, all from hospitals, airports, food industry to small apartments
General industry:
• Clean and corrosion free production and piping systems
• Increased heat transfer rate
• Prevents and removes scaling
• Cleans wastewater and drain pipes
• Prevents bad smell
• All areas washed with Biowater will be disinfected, included handwash and bodywash
• Biofilm, algae, algae toxins and scaling removal
• Reduced Maintenance Costs
Aquaculture:
• Ice frozen with hydrogen water keeps the fish fresh a lot longer than normal water
• Biofilm, algae, algae toxins and scaling removal
• Evenly oxygenates the entire water column
• Keeps all piping, pumps and machinery clean and 100% disinfected at all time
• Reduced Maintenance Costs
• All areas washed with Biowater will be disinfected, included handwash and bodywash
• No more bad smell
• Significant inhibition effect on corrosion
• Cleans wastewater and drain pipes
• Keeps holding tanks clean
• Keeps waste tanks clean and odour free
• Significantly improve the immune response
• Decreases oxidative stress considerably
• Improved growth rate
• Enhancing disease resistance capabilities
ISO 20480-1:2017 Bubble size definition
Microbubbles: Greater than 1 and less than 100 μm
Fine bubble: Less than 100 μm
Ultrafine bubbles: Less than 1 μm, normally between 100 and 200 nm
Nanobubble is old term for Ultrafine bubbles